title: "Door Interlocking (U.S.) - Control Panel Tip | Siemens"
description: "Learn how secure door interlocking in panel building helps protect operators, prevent unauthorized access, and support machine safety and compliance."
language: "sk-SK"
locale: "sk-SK"
source_url: "https://www.siemens.com/sk-sk/industries/industrial-machinery/control-panels/panel-building-door-locking"
url: "https://www.siemens.com/sk-sk/industries/industrial-machinery/control-panels/panel-building-door-locking/"
canonical: "https://www.siemens.com/sk-sk/industries/industrial-machinery/control-panels/panel-building-door-locking/"
image: "https://images.sw.cdn.siemens.com/siemens-disw-assets/public/35XAgWl10aMh8ItDnKVwoa/en-US/control-panel-tip-panel-building-door-locking-1200x630.jpg?auto=format%2Ccompress&amp;w=1200&amp;h=630&amp;fit=crop&amp;crop=faces%2Cedges&amp;q=60"
type: "website"
content_category: "faq"
division: "SI EP"
schema_type: "WebPage"
schema_types:
  - "WebPage"
  - "FAQPage"
site_name: "Siemens"
fetched_at: "2026-11-13T05:15:44Z"
word_count: 1144
reading_time_minutes: 5
links_count: 12
images_count: 7
status_code: 200
twitter_card: "summary_large_image"
---

## Structured Data (JSON-LD)

```json
{
  "@context": "https://schema.org",
  "@type": "WebPage",
  "name": "Electric/electronic door interlocking (U.S. standards)",
  "url": "https://www.siemens.com/sk-sk/industries/industrial-machinery/control-panels/panel-building-door-locking/",
  "breadcrumb": {
    "@type": "BreadcrumbList",
    "itemListElement": [
      {
        "@type": "ListItem",
        "position": 1,
        "item": {
          "name": "",
          "@id": "https://www.siemens.com/sk-sk/"
        }
      },
      {
        "@type": "ListItem",
        "position": 2,
        "item": {
          "name": "Priemyselné odvetvia",
          "@id": "https://www.siemens.com/sk-sk/industries/"
        }
      },
      {
        "@type": "ListItem",
        "position": 3,
        "item": {
          "name": "Priemyselné stroje",
          "@id": "https://www.siemens.com/sk-sk/industries/industrial-machinery/"
        }
      },
      {
        "@type": "ListItem",
        "position": 4,
        "item": {
          "name": "Ovládacie panely",
          "@id": "https://www.siemens.com/sk-sk/industries/industrial-machinery/control-panels/"
        }
      },
      {
        "@type": "ListItem",
        "position": 5,
        "item": {
          "name": "Door Interlocking (U.S.)",
          "@id": "https://www.siemens.com/sk-sk/industries/industrial-machinery/control-panels/panel-building-door-locking/"
        }
      }
    ]
  },
  "producer": {
    "@type": "Organization",
    "name": "Siemens"
  },
  "publisher": {
    "@type": "Organization",
    "name": "Siemens"
  },
  "maintainer": {
    "@type": "Organization",
    "name": "Siemens",
    "department": [
      {
        "@type": "Organization",
        "name": "SI EP"
      }
    ]
  }
}
```

```json
{
  "@context": "https://schema.org",
  "@type": "FAQPage",
  "mainEntity": [
    {
      "@type": "Question",
      "name": "Which options do I have for restricting control panel access?",
      "acceptedAnswer": {
        "@type": "Answer",
        "text": "<p>When a control panel supplies industrial machinery with electrical power and operates under a voltage ≥ 50 V AC/60 V DC, the panel can be opened only subject to at least one of the following three conditions. You are advised to discuss these three options with the operator of the control panel or industrial machinery. </p><p><b>Option #1: Door interlocking with only a tool or key</b><br>In this case, the following three conditions must be met: </p><ul><li>The doors can be opened only with a key or tool (e.g. double-bit key).</li><li>All live parts must be protected against unintentional direct contact by 50 mm sphere minimum (back of hand proof).</li><li>The accompanying warning must be affixed to the door so that it is visible on the outside of the control panel.</li></ul><p><b>Option #2: Door interlocking by the main disconnecting device (main switch)</b><br>The industrial control panel's main disconnecting device is interlocked so that the doors can only be opened when the electrical power has been switched off. This door interlocking can be mechanical, electrical, or a combination of the two. <br>Interlocking (=snap lock function) must be automatically activated without additional actions being taken when the doors are closed under voltage. </p><p><b>Option #3: Overridable interlocking is also optionally possible</b><br>Interlocking can be defeated by a qualified person using a tool so that the door can be opened for service, maintenance, and troubleshooting even with the main switch switched on. If you decide in favor of an interlocking which is able to be defeated, all of the following points must be taken into account: </p><ul><li>Disconnection of the main disconnecting device: Regardless of the door position, it must be possible to open the main disconnecting device without a tool and lock it in the OFF position at any time with a lock. </li><li>Protection against unintentional switching on: When the door is open and the mains disconnecting device is switched off, an unintentional switching on of the main disconnecting device must be prevented. Exception: A qualified person can also switch it on when the door is open by means of a deliberate action. </li><li>Basic protection (protection against direct contact): All live parts must at least be back-of-hand-proof (50 mm sphere).</li></ul><p>All relevant information on door interlocking and the override functions must be contained in the documentation for the electrical equipment. </p><p><b>Covering the live parts</b><br>Alternatively to the other two options, the control panel can be opened and operated by any person unqualified in electrical technology. In this case, all live components must be physically enclosed or covered so that no bodily contact with the parts of the electrical equipment is possible. In this case, the doors require neither locks (see #1)  nor interlocking with the main disconnecting devices (see #2). A corresponding warning must be affixed to the control panel doors according to NFPA 79.</p> <div class=\"rtfImg-\"><img src=\"https://images.sw.cdn.siemens.com/siemens-disw-assets/public/7qL9u0dM6tpkIw3QEPSRvi/en-US/e1c4b072-b664-4593-9b1a-f33b1eafb1cdControl-Panel-Door-Interlock-USA-label-UL508A-NFPA79-1920x1080.png?auto=format%2Ccompress&amp;w=1280&amp;h=720&amp;fit=crop&amp;crop=faces%2Cedges&amp;q=60\" alt=\"CAUTION: Power off before opening; close it before restoring power. WARNING: Main disconnect doesn't deenergize all circuits.\" style=\"display:block;width:100%;height:auto;aspect-ratio:16/9\" loading=\"lazy\"></div>"
      }
    },
    {
      "@type": "Question",
      "name": "Are there exceptions that do not need restricted access?",
      "acceptedAnswer": {
        "@type": "Answer",
        "text": "<p>Under certain conditions, you do not have to restrict access by design:</p><ul><li>The control panel’s operating voltage is less than 50 V AC or 60 V DC</li><li>The control panel does not supply an industrial machinery</li></ul>"
      }
    },
    {
      "@type": "Question",
      "name": "How does electric interlocking work? (Application example)",
      "acceptedAnswer": {
        "@type": "Answer",
        "text": "<p>For reasons of space, it is often necessary that the electrical control of a machine or plant be distributed over multiple control panels, such as side-by-side or distributed control panels. These control panels can be supplied by a main cabinet with a corresponding main disconnecting device. <br>If you now want to implement the unlocking and opening of all control panel doors in combination with the main disconnecting device (door interlocking), expenditures for the design and construction of a purely mechanical solution can quickly become high and impractical.<br>An EPLAN project of the electric classic door interlocking, and the complete documentation of the application solutions are available under the following <a href=\"https://support.industry.siemens.com/cs/document/109762616/door-interlocking-for-distributed-industrial-control-panels-according-to-ul-508a-and-nfpa-79-?dti=0&amp;lc=en-ww\">link</a> </p><div class=\"rtfImg-\"><img src=\"https://images.sw.cdn.siemens.com/siemens-disw-assets/public/137I10EGMwuuXXg4YNBlhD/en-US/3dfa20c2-5357-4149-8b35-4d31fef03d04-ICP-Door-Interlock-Application-Eplan-classic-interlock-electrical-1920x1080.png?auto=format%2Ccompress&amp;w=1280&amp;h=720&amp;fit=crop&amp;crop=faces%2Cedges&amp;q=60\" alt=\"Monochrome electrical circuit diagram showing contactors and Siemens branding, with the marking 3VA9978-0BF23.\" style=\"display:block;width:100%;height:auto;aspect-ratio:16/9\" loading=\"lazy\"></div><p>Door interlocking in the main cabinet is implemented mechanically by means of the door-coupling rotary operating mechanism of the 3VA molded case circuit breaker being used as a main switch. The distributed control panels are equipped with electric door interlocking.<br>The core of the application is a position switch with a tumbler that is situated directly on the door of the distributed control panels and has two important functions: It interlocks the door when the main switch is switched on and it signals whether the door is open or closed. This can prevent the main switch from being switched on even though the door of a distributed control panel is still open.</p><p><a href=\"/sk-sk/products/sirius/\">Learn more about SIRIUS position and safety switches</a></p><p>If necessary for service and maintenance, an override of the distributed control panels is very easy to implement. In this application, a timing relay is controlled via a key-operated pushbutton. With the timing relay, door interlocking is disabled for a set time period and the control panel can be opened with live components.<br>Three indicator lights located on the main cabinet indicate the following:</p><ul><li>First light: All doors are closed and locked</li><li>Second light: Main switch is switched on</li><li>Third light: Override active (door interlocking temporarily suspended)</li></ul><p><a href=\"/sk-sk/products/sirius/\">Learn more about SIRIUS ACT pushbuttons and indicator lights</a></p>"
      }
    },
    {
      "@type": "Question",
      "name": "How does electronic interlocking work? (Application example)",
      "acceptedAnswer": {
        "@type": "Answer",
        "text": "<p>Door interlocking can just as easily be controlled via a LOGO! program or via a SIMATIC program block. </p><p>Prefabricated SIMATIC program blocks, EPLAN projects, and complete documentation are available under the following link: </p><p><a href=\"https://support.industry.siemens.com/cs/document/109762616/door-interlocking-for-distributed-industrial-control-panels-according-to-ul-508a-and-nfpa-79-?dti=0&amp;lc=en-ww\">Door interlocking for distributed industrial control panels according to UL 508A and NFPA 79</a></p><p><a href=\"https://www.siemens.com/en-us/products/logo/basic-modules/\">Website LOGO! basic modules</a></p> "
      }
    }
  ]
}
```

Door Interlocking (U.S.) - Control Panel Tip | Siemens

![](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/1GqxpbWJzAj1cYj4lVRBX8/en-US/control-panel-tip-panel-building-door-locking-2560x1440.jpg?auto=format%2Ccompress&w=2560&h=1440&fit=crop&crop=faces%2Cedges&q=60)

# Electric/electronic door interlocking (U.S. standards)

Control panel tip: Restricted access to industrial control panels in accordance with UL508A and NFPA 79.

## Did you know door locking must meet safety standards?

Industrial control panels used in the U.S. must be designed with protection against direct contact, ensuring no live parts can be touched during normal operations. U.S. standards specify that enclosure doors must be locked in accordance with UL 508A and NFPA 79, while remaining accessible for maintenance and service.

![8a5d2ad2-5055-4901-8113-8c17e38c9f31-UL-control-cabinet-doors-closed-16to9-3840x2160](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/4VDAyZlIUNcfj0h0cxqRu0/en-US/8a5d2ad2-5055-4901-8113-8c17e38c9f31-UL-control-cabinet-doors-closed-16to9-3840x2160.png?auto=format%2Ccompress&w=1280&h=720&fit=crop&crop=faces%2Cedges&q=60)

## Time-saving tips for your project

### When a control panel supplies industrial machinery with electrical power and operates under a voltage ≥ 50 V AC/60 V DC, the panel can be opened only subject to at least one of the following three conditions. You are advised to discuss these three options with the operator of the control panel or industrial machinery.

**Option #1: Door interlocking with only a tool or key** 
In this case, the following three conditions must be met:

* The doors can be opened only with a key or tool (e.g. double-bit key).
* All live parts must be protected against unintentional direct contact by 50 mm sphere minimum (back of hand proof).
* The accompanying warning must be affixed to the door so that it is visible on the outside of the control panel.

**Option #2: Door interlocking by the main disconnecting device (main switch)** 
The industrial control panel's main disconnecting device is interlocked so that the doors can only be opened when the electrical power has been switched off. This door interlocking can be mechanical, electrical, or a combination of the two. 
Interlocking (=snap lock function) must be automatically activated without additional actions being taken when the doors are closed under voltage.

**Option #3: Overridable interlocking is also optionally possible** 
Interlocking can be defeated by a qualified person using a tool so that the door can be opened for service, maintenance, and troubleshooting even with the main switch switched on. If you decide in favor of an interlocking which is able to be defeated, all of the following points must be taken into account:

* Disconnection of the main disconnecting device: Regardless of the door position, it must be possible to open the main disconnecting device without a tool and lock it in the OFF position at any time with a lock.
* Protection against unintentional switching on: When the door is open and the mains disconnecting device is switched off, an unintentional switching on of the main disconnecting device must be prevented. Exception: A qualified person can also switch it on when the door is open by means of a deliberate action.
* Basic protection (protection against direct contact): All live parts must at least be back-of-hand-proof (50 mm sphere).

All relevant information on door interlocking and the override functions must be contained in the documentation for the electrical equipment.

**Covering the live parts** 
Alternatively to the other two options, the control panel can be opened and operated by any person unqualified in electrical technology. In this case, all live components must be physically enclosed or covered so that no bodily contact with the parts of the electrical equipment is possible. In this case, the doors require neither locks (see #1) nor interlocking with the main disconnecting devices (see #2). A corresponding warning must be affixed to the control panel doors according to NFPA 79.

![CAUTION: Power off before opening; close it before restoring power. WARNING: Main disconnect doesn't deenergize all circuits.](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/7qL9u0dM6tpkIw3QEPSRvi/en-US/e1c4b072-b664-4593-9b1a-f33b1eafb1cdControl-Panel-Door-Interlock-USA-label-UL508A-NFPA79-1920x1080.png?auto=format%2Ccompress&w=1280&h=720&fit=crop&crop=faces%2Cedges&q=60)

### For reasons of space, it is often necessary that the electrical control of a machine or plant be distributed over multiple control panels, such as side-by-side or distributed control panels. These control panels can be supplied by a main cabinet with a corresponding main disconnecting device. 
If you now want to implement the unlocking and opening of all control panel doors in combination with the main disconnecting device (door interlocking), expenditures for the design and construction of a purely mechanical solution can quickly become high and impractical. 
An EPLAN project of the electric classic door interlocking, and the complete documentation of the application solutions are available under the following [link](https://support.industry.siemens.com/cs/document/109762616/door-interlocking-for-distributed-industrial-control-panels-according-to-ul-508a-and-nfpa-79-?dti=0&lc=en-ww)

![Monochrome electrical circuit diagram showing contactors and Siemens branding, with the marking 3VA9978-0BF23.](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/137I10EGMwuuXXg4YNBlhD/en-US/3dfa20c2-5357-4149-8b35-4d31fef03d04-ICP-Door-Interlock-Application-Eplan-classic-interlock-electrical-1920x1080.png?auto=format%2Ccompress&w=1280&h=720&fit=crop&crop=faces%2Cedges&q=60)

Door interlocking in the main cabinet is implemented mechanically by means of the door-coupling rotary operating mechanism of the 3VA molded case circuit breaker being used as a main switch. The distributed control panels are equipped with electric door interlocking. 
The core of the application is a position switch with a tumbler that is situated directly on the door of the distributed control panels and has two important functions: It interlocks the door when the main switch is switched on and it signals whether the door is open or closed. This can prevent the main switch from being switched on even though the door of a distributed control panel is still open.

[Learn more about SIRIUS position and safety switches](/sk-sk/products/sirius/)

If necessary for service and maintenance, an override of the distributed control panels is very easy to implement. In this application, a timing relay is controlled via a key-operated pushbutton. With the timing relay, door interlocking is disabled for a set time period and the control panel can be opened with live components. 
Three indicator lights located on the main cabinet indicate the following:

* First light: All doors are closed and locked
* Second light: Main switch is switched on
* Third light: Override active (door interlocking temporarily suspended)

[Learn more about SIRIUS ACT pushbuttons and indicator lights](/sk-sk/products/sirius/)

### Door interlocking can just as easily be controlled via a LOGO! program or via a SIMATIC program block.

Prefabricated SIMATIC program blocks, EPLAN projects, and complete documentation are available under the following link:

[Door interlocking for distributed industrial control panels according to UL 508A and NFPA 79](https://support.industry.siemens.com/cs/document/109762616/door-interlocking-for-distributed-industrial-control-panels-according-to-ul-508a-and-nfpa-79-?dti=0&lc=en-ww)

[Website LOGO! basic modules](https://www.siemens.com/en-us/products/logo/basic-modules/)

## Practical knowledge for control cabinet design

[

![Monochrome electrical circuit diagram showing contactors and Siemens branding, with the marking 3VA9978-0BF23.](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/137I10EGMwuuXXg4YNBlhD/en-US/3dfa20c2-5357-4149-8b35-4d31fef03d04-ICP-Door-Interlock-Application-Eplan-classic-interlock-electrical-1920x1080.png?auto=format%2Ccompress&w=640&h=360&fit=crop&crop=faces%2Cedges&q=60)

**Application example**

### Door interlocking for control cabinets

Learn how electric and electronic door interlocking enables safe access to distributed control panels. The application example shows how interlocking with the main disconnect reduces complexity compared to mechanical solutions.

](https://support.industry.siemens.com/cs/document/109762616/door-interlocking-for-distributed-industrial-control-panels-according-to-ul-508a-and-nfpa-79-?lc=en-de)

[

![A gray Siemens LOGO! device has buttons and a smiley-face display beside a connected-node graphic.](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/5dtCve1P07doTO6vgYRxwK/en-US/ee9e8d27-be6d-4c7c-8b8a-86c8bd4ee045-8697-00-Logo-Cloud-Still-200909-1-CMYK-1280x720.jpg?auto=format%2Ccompress&w=640&h=360&fit=crop&crop=faces%2Cedges&q=60)

**Software & logic control**

### Electronic door interlocking with LOGO!

See how electronic door interlocking can be implemented using LOGO! logic modules or SIMATIC program blocks, including time-based overrides for service and maintenance scenarios.

](/sk-sk/products/logo/)

[

![feefbad750fb28c323e4a9e8dc53d21092eb1861-positionsschalter3se5-1920x1080](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/7DTwuksYNM1t0iLORLKwp3/en-US/feefbad750fb28c323e4a9e8dc53d21092eb1861-positionsschalter3se5-1920x1080.jpg?auto=format%2Ccompress&w=640&h=360&fit=crop&crop=faces%2Cedges&q=60)

**Product solution**

### SIRIUS position and safety switches

With SIRIUS, we offer you a unique comprehensive portfolio for every industrial control application. The major advantages: With their modular design, our products can be planned and built into a control cabinet in a simple way.

](/sk-sk/products/sirius/act/)