SITOP PSU8600 – the unique power supply system with PROFINET

image

An integrated power supply is the future. Or is already reality today.

SITOP PSU8600 is the first power supply system with full integration in Totally Integrated Automation. This pays off both in engineering in the TIA Portal and in actual operation. For example, voltage and current can be individually adjusted for each output, and the integrated overload protection enables each output to be monitored. Other modules from the system toolbox can be added to suit requirements with no wiring overhead, for example to buffer power failures. Comprehensive diagnostic and maintenance information is available via PROFINET. SITOP provides the best possible support for power management for plants or machines, from recording power data from individual outputs to switching outputs on and off via PROFIenergy. In this way, the SITOP PSU8600 is setting new standards in plant reliability and efficiency.

Our experts will be happy to help you.
Contact us

Portfolio – overview of all system components

image
SITOP PSU8600 base units

SITOP PSU8600 base units

Great performance in a very small space

The high efficiency up to 94% of the basic devices ensures minimum heat loss, which makes very compact designs possible. Up to four outputs monitored for overloads also help save space for circuit-breaking devices. Integrated Ethernet/PROFINET communication opens up new opportunities for diagnostics and the range of applications for your power supply. 

 

  • 3-phase power supply, nominal output current 20 A or 40 A at 24 V DC 
  • One or four outputs monitored for overload, individually adjustable from 5 V to 28 V
  • Integrated Ethernet/PROFINET interface with two ports
  • Easy configuration in the TIA Portal
  • Extensive diagnostic information and adjustment options with the system in operation
  • Extremely narrow installation width 80/125/100 mm
image
SITOP CNX8600 expansion modules

SITOP BUF8600 buffer modules

Bridging brief and longer power failures

Buffer modules with electrolytic capacitors, providing buffering for up to 600 ms at a load current of 40 A, can be used to protect against brief power dips on the line side (brownouts). The versions with double-layer capacitors (UltraCaps) buffer against longer outages up to 20 s at 40 A. Because the buffer time is longer for lower buffer currents, this enables industrial PCs to be shut down manually as required. 

 

  • Base unit capable of being combined with up to two buffer modules to suit requirements
  • Easy to connect using the System Clip Link, a connector for system data and power supply
  • Output voltage: 24 V DC (setting range 5 V to 28 V per output)
  • Max. four expansion modules per base unit le
  • Narrow installation width: 60 mm
image
SITOP BUF8600 buffer modules

SITOP BUF8600 buffer modules

Bridging brief and longer power failures

Buffer modules with electrolytic capacitors, providing buffering for up to 600 ms at a load current of 40 A, can be used to protect against brief power dips on the line side (brownouts). The versions with double-layer capacitors (UltraCaps) buffer against longer outages up to 20 s at 40 A. Because the buffer time is longer for lower buffer currents, this enables industrial PCs to be shut down manually as required. 

 

  • Base unit capable of being combined with up to two buffer modules to suit requirements
  • Easy to connect using the System Clip Link, a connector for system data and power supply
  • Installed widths: 60/125 mm

Integrated power supply and system

Complex systems place highest demands on their components in terms of efficiency, flexibility and reliability. The innovative SITOP PSU8600 power supply system meets them all – thanks to a unique functionality, diagnostic capability, complete integration into TIA, and modular expandability.

Top integration – with complete system integration

SITOP PSU8600 is the first power supply system that is completely embedded in Totally Integrated Automation (TIA). Not only does this facilitate especially easy, fast and convenient engineering in the TIA Portal, but also extensive evaluation of operating and diagnostics data as well as energy management functions. SITOP PSU8600 with its Industrial Ethernet/PROFINET switch functionality, with two ports on the base units, can be perfectly incorporated into existing automation networks in both in-line and ring structures. The integrated Web server also allows power supply monitoring or diagnosis to be performed remotely.

Top efficiency – from engineering through to operation

Thanks to its compact and modular system design, SITOP PSU8600 can be adapted to address the widest range of requirements, and when necessary, can be flexibly expanded. Because every output can be flexibly set between 5 V and 28 V, there is no need for additional power supply units to run 5 V or 12 V consumers, for instance. And when it comes to energy saving, the system has proven to be highly efficient. Thanks to the very high efficiency rating of the base units (up to 94%), for example, and support for PROFIenergy, individual power supply outputs can be switched off during breaks to save power. And in operation, the system senses the voltage and current data for each individual output, therefore ensuring transparency of the load behavior. This energy data can also be forwarded to higher-level power management systems: for processing and determining potential for energy saving.

 

 

 

Top reliability – thanks to selectivity and monitoring

SITOP PSU8600 offers the optimum basis to identify and eliminate faults at an early stage, initiate preventive maintenance and avoid plant downtimes. This includes monitoring all of the outputs – and selectively switching them off when a fault develops, for instance. As a consequence, a short circuit or an overload at an individual load does not mean that the complete plant or system shuts down. 50% extra power for short-term loads as well as the ability to buffer brief power failures up to 20 seconds at a full 40 A load are further advantages that the SITOP PSU8600 can offer. Additionally, the buffer operation is signaled for brief line-side voltage dips, and the time that the power actually failed – an ideal indicator to evaluate line quality.

More highlights of the power supply system

References & applications

An integrated power supply is mere theory. Or has long become practice.

From engineering to operation, the powerful, modular SITOP PSU8600 power supply system gives users many advantages for supplying DC power to machines.

image
image
image
image

Downloads, Support, Services

You can note information down. Or download it.

Download brochures and documentation with more details on the SITOP PSU8600 power supply system here. Support links take you to system-specific FAQs, manuals, product notes and technical data. Discover our range of practical services at the same time.

image

The fastest way to the experts

Proposed solutions for your queries and direct access to our experts in Technical Support

Support request (SIOS)
image

Special investigation

Special investigations analyze the causes of problems that have been occurring more frequently with no explanation.

Special investigation
image

Logistical handling of returned goods from service processes

Central returns processing at the Service Logistics Center in Erlangen

Return delivery address: Siemens AG Retouren Center c/o Geis Industrie-Service GmbH, Tor 1-4, Kraftwerkstr. 25a, 91056 Erlangen, Germany

You can puzzle over something for ages. Or just ask.

If you would like to know even more about our modular SITOP PSU8600 power supply system, or if you have any questions, just talk to our experts. They will be glad to assist you.

Would you like to know more?
Contact us