---
title: "SENTRON Powermanager | Siemens"
description: "SENTRON Powermanager software is your comprehensive electrical power monitoring system (EPMS) with advanced functions."
language: "en-US"
locale: "en-US"
source_url: "https://www.siemens.com/en-us/products/sentron/powermanager/"
url: "https://www.siemens.com/en-us/products/sentron/powermanager/"
canonical: "https://www.siemens.com/en-us/products/sentron/powermanager/"
image: "https://images.sw.cdn.siemens.com/siemens-disw-assets/public/CXYBU9rsuFc2gf1XC4eki/en-US/5606d18d-8989-4bd9-a925-b897f748893d-p-i201-xx-09056v-sentron-powermanager-keyvisual-1200x630.jpg?auto=format%2Ccompress&amp;w=1200&amp;h=630&amp;fit=crop&amp;crop=faces%2Cedges&amp;q=60"
type: "website"
content_category: "faq"
division: "SI EP"
schema_type: "WebPage"
schema_types:
  - "WebPage"
  - "FAQPage"
site_name: "Siemens"
fetched_at: "2026-11-16T13:31:13Z"
word_count: 763
reading_time_minutes: 3
links_count: 19
images_count: 7
status_code: 200
twitter_card: "summary_large_image"
---

## Structured Data (JSON-LD)

```json
{
  "@context": "https://schema.org",
  "@type": "WebPage",
  "name": "SENTRON Powermanager for smart infrastructures",
  "url": "https://www.siemens.com/en-us/products/sentron/powermanager/",
  "breadcrumb": {
    "@type": "BreadcrumbList",
    "itemListElement": [
      {
        "@type": "ListItem",
        "position": 1,
        "item": {
          "name": "",
          "@id": "https://www.siemens.com/en-us/"
        }
      },
      {
        "@type": "ListItem",
        "position": 2,
        "item": {
          "name": "Products",
          "@id": "https://www.siemens.com/en-us/products/"
        }
      },
      {
        "@type": "ListItem",
        "position": 3,
        "item": {
          "name": "SENTRON low-voltage products",
          "@id": "https://www.siemens.com/en-us/products/sentron/"
        }
      },
      {
        "@type": "ListItem",
        "position": 4,
        "item": {
          "name": "SENTRON Powermanager",
          "@id": "https://www.siemens.com/en-us/products/sentron/powermanager/"
        }
      }
    ]
  },
  "producer": {
    "@type": "Organization",
    "name": "Siemens"
  },
  "publisher": {
    "@type": "Organization",
    "name": "Siemens"
  },
  "maintainer": {
    "@type": "Organization",
    "name": "Siemens",
    "department": [
      {
        "@type": "Organization",
        "name": "SI EP"
      }
    ]
  }
}
```

```json
{
  "@context": "https://schema.org",
  "@type": "FAQPage",
  "mainEntity": [
    {
      "@type": "Question",
      "name": "Which types of reports are supported by SENTRON Powermanager?",
      "acceptedAnswer": {
        "@type": "Answer",
        "text": "<p>Types of report supported from absolute energy …</p><ul><li><b>Absolute energy: </b>Display of the absolute energy consumption of the data points for selected time intervals</li><li><b>Energy analysis:</b> Overview of power demand curves<br>Total energy consumption: Display of all energy consumption for a selected time period</li><li><b>Load duration:</b> Report with power demand values and the duration of each power demand value used in the selected time period</li><li><b>Load variance: </b>Power demand values for the selected time period and range of the power demand values for the individual times</li><li><b>Standard report:</b> Display of all the values of the selected data points for a selected time period in a table<br><br>… to top 10 energy consumers</li><li><b>Cost center report: </b>Calculates the total energy consumption and costs for the different media associated with each cost center</li><li><b>Power peaks:</b> Identification of power peaks within a defined time period using the integrated report generator</li><li><b>Sankey report: </b>Visualization of energy flows and their distribution within the location or company</li><li><b>Top 10 energy consumers:</b> Report with details on the top 10 consumers of active and reactive energy</li><li><b>IEEE 519 report: </b>Displays the analysis of the harmonic compliance of the selected source in accordance with IEEE 519-2022 standard</li><li><b>EN 50160 report:</b> Displays the total power quality variations occurred over the selected time (last 7 days)</li></ul>"
      }
    },
    {
      "@type": "Question",
      "name": "Do reports created with SENTRON Powermanager count as proof of ISO 50001?",
      "acceptedAnswer": {
        "@type": "Answer",
        "text": "<p>SENTRON Powermanager is TÜV certified for ISO 50001. </p><p><a href=\"https://support.industry.siemens.com/cs/document/109779332/general-product-approval-t%C3%BCv-t%C3%BCv-rhineland?dti=0&amp;lc=en-ww\">Learn more about the product approval</a></p>"
      }
    },
    {
      "@type": "Question",
      "name": "What are the supported device types?",
      "acceptedAnswer": {
        "@type": "Answer",
        "text": "<p><b>Supported device types</b></p><p>Field devices supported by SENTRON Powermanager include:</p><ul><li>Energy meters and multifunction measuring devices</li><li>Meters to measure power quality</li><li>Multichannel current measuring devices</li><li>Circuit-breakers and communication-capable circuit protection devices</li><li>Converters</li><li>Virtual meters/logical devices</li><li>Devices from third-party vendors</li><li>PLCs and controllers</li></ul>"
      }
    },
    {
      "@type": "Question",
      "name": "What are the system-specific details and requirements?",
      "acceptedAnswer": {
        "@type": "Answer",
        "text": "<p><b>Interfaces and system limits</b></p><p>SENTRON Powermanager is distinctive for its extreme openness:</p><ul><li>Connection of field devices via Modbus TCP (Modbus RTU devices via gateway), IEC 61850, or BACnet</li><li>History database based on Microsoft® SQL Server</li><li>Up to 1,000 devices per server</li></ul><p><a href=\"https://support.industry.siemens.com/cs/document/109771760/sentron-powermanager?dti=0&amp;lc=en-ww\">See detailed system requirements</a><br><br><b>System requirements</b></p><p>SENTRON Powermanager places the following requirements on the hardware and IT environment:</p><ul><li>Hardware requirements: processor: Intel Core i7 ≥ 3.2 GHz/min. 64-GB RAM/hard disk: SSD with 1,024 GB of available memory/NGA display with min. 1600 x 900 pixels, 16-bit color depth</li><li>Operating systems supported: Windows® 10 LTSB 2016, Windows® 10 LTSC 2019, Windows® 11 Enterprise/Professional (64-bit), Windows® Server 2019 (64-bit), 2022 (64-bit), 2025 (64-bit)</li><li>Virtualization: Microsoft® Hyper-V 2016, VMware vSphere 6.0, 6.5 and 6.7</li></ul>"
      }
    }
  ]
}
```

SENTRON Powermanager | Siemens

# SENTRON Powermanager

SENTRON Powermanager – your EMS and EPMS solution for energy management and electrical power monitoring in industry, buildings, data centers and infrastructure.

![Three dark-bordered monitors on stands show data on the left, charts in the center, and a schematic diagram on the right.](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/6O7S3AXoS0dnWqPsUh8U3A/en-US/5606d18d-8989-4bd9-a925-b897f748893d-p-i201-xx-09056v_powermanager-640x480.jpg?auto=format%2Ccompress&w=640&h=480&fit=crop&q=60)

Let's connect

Contact us for sales and pricing information.

[Select & order](https://sieportal.siemens.com/en-ww/products-services/10057619?tree=CatalogTree)

## Why SENTRON Powermanager?

Transparency for lower energy costs and higher plant availability: SENTRON Powermanager lets energy managers, energy consultants, and facility managers monitor energy consumption in buildings and plants, keep an eye on the condition of their power distribution and on the power quality, and generate reports for operational energy management according to ISO 50001. The software has everything you need for comprehensive energy management – from secure rights management and a wide range of report types to flexible software updates. In addition, the software supports both SENTRON devices and all other devices, including third-party devices, with a system upper limit of 1,000 devices per server.

## Key benefits

### Increase energy and cost efficiency

Gain transparency over energy consumption and use load management to optimize operations.

### Higher reliability and availability

Make use of predictive maintenance to avoid unplanned downtime and maximize the availability of your low-voltage distribution systems.

### Stay compliant with ISO norms

Create reports with SENTRON Powermanager for operational energy management according to ISO 50001.

## Featured capabilities

## Comprehensive power reporting

**High energy transparency thanks to comprehensive reporting**

* Data processing and export for a wide range of energy reports such as absolute energy, load variance, cost center report, sankey report, top 10 energy consumers, etc.
* Integrated long-term archive for data analysis over longer time periods
* Reporting and report storage in multiple formats
* Possibility of forwarding reports to an e-mail list or folder

![ab325d64-03c4-4c0e-8a5a-5d1e8998cf26-pm-90-PAC3220-Energymanagement-bright-1280x720](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/4JUROGDehACg2DXyED2dl4/en-US/ab325d64-03c4-4c0e-8a5a-5d1e8998cf26-pm-90-PAC3220-Energymanagement-bright-1280x720.png?auto=format%2Ccompress&w=1280&h=720&fit=crop&crop=faces%2Cedges&q=60)

## Reliable power quality monitoring

**Higher availability and efficiency thanks to transparent power quality**

* Simple, preconfigured, and browser-based dashboards at the device, area, and system level for assessing power quality according to EN 50160
* Alarms in the event of voltage deviations, harmonics, voltage sags and swells, as well as transients
* EN 50160-compliant reporting
* Monitoring with PQ Advisor in SENTRON Powermanager via IEC 61850 protocol with power quality instruments [SICAM Q100](https://www.siemens.com/en-us/products/sicam/q100-power-quality-instrument/) and [SICAM Q200](https://www.siemens.com/en-us/products/sicam/q200-power-quality-recorder/)

[Read more in our factsheet 'Power quality for data centers'](https://assets.new.siemens.com/siemens/assets/api/uuid:ef5bddcf-0124-4eb6-acec-3d6a1ecf8b3d/siep-t10452-00-7600dbpowerqualityfordatacentersonlineen-144.pdf)

## **Reliable condition monitoring**

**Higher availability thanks to reliable condition monitoring**

* System-wide health dashboard and individual displays with important KPIs for integrated diagnostics, fault, and maintenance management
* Information on the condition of the circuit-breakers (SENTRON 3VA and 3WA), such as the health status as an exact percentage and expected remaining life

**Your benefits for condition monitoring and maintenance management**

* Predefined standard views available, possibility of tailored adaptation
* Fast locating of errors and faults and prevention of shutdowns
* Preventive planning of maintenance jobs

![7aa89d96-6b72-4fa4-a87b-8005aae51b43-pm-90-udv-healthdashboard-1280x720](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/4QSHLXEJrWuOUmpQwPZRmr/en-US/7aa89d96-6b72-4fa4-a87b-8005aae51b43-pm-90-udv-healthdashboard-1280x720.png?auto=format%2Ccompress&w=1280&h=720&fit=crop&crop=faces%2Cedges&q=60)

![480423a1-9412-4e58-8581-c27ca36f4ce2-pm-80-sentron-powermanager-cost-center-1280x720](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/53Uspx1PrHTHZef27dvW2t/en-US/480423a1-9412-4e58-8581-c27ca36f4ce2-pm-80-sentron-powermanager-cost-center-1280x720.png?auto=format%2Ccompress&w=1280&h=720&fit=crop&crop=faces%2Cedges&q=60)

## Flexible commissioning

**Individually adaptable user interface, dashboards, and reports**

* Individually definable alarms, alarm lists, adaptable device templates and configurable dashboards
* Company logo(s) or defined headers and footers can be added to standard report templates
* Reports structure with multiple folders and report generation and storage in multiple formats possible
* Standardized graphics library with hundreds of predefined elements for quickly generating animated graphics that can be tailored to a specific project
* Optional graphics editor for a customized design that can also be used on other SENTRON Powermanager systems without additional installations

## Frequently asked questions

### Explore related resources and products

### Factsheets

[Factsheet](https://assets.new.siemens.com/siemens/assets/api/uuid:89eba0f3-d0ce-4203-934e-16a9d70cfd9d/siep-b10149-01-00dedatenblattsentronpowermanagerenus-144.pdf) | Software SENTRON Powermanager

[Factsheet](https://assets.new.siemens.com/siemens/assets/api/uuid:bee44419-ff17-445d-aa4f-e7857eaec6f3/siep-b10360-01-00de-db-sentron-powermanager-sur-sus-deenus-144.pdf) | Update your SENTRON Powermanager

[Factsheet](https://assets.new.siemens.com/siemens/assets/api/uuid:cc374e0e-9d19-4e2c-9061-1326a8859517/siep-b10476-00-7600sentron-powermanager-power-quality-en-144.pdf) | Reliable monitoring of power quality

[Factsheet](https://assets.new.siemens.com/siemens/assets/api/uuid:ef5bddcf-0124-4eb6-acec-3d6a1ecf8b3d/siep-t10452-00-7600dbpowerqualityfordatacentersonlineen-144.pdf) | Power quality for data centers

[Factsheet](https://assets.new.siemens.com/siemens/assets/api/uuid:f93b87a4-0a86-40d5-afb9-73f2bcefd71c/siep-b10091-00-00dewhitepaperiso50003deo2eenus-72.pdf) | ISO 5001 compulsory verification

### Guides

[Guide](https://assets.new.siemens.com/siemens/assets/api/uuid:56e704c3-6b73-4fd4-a6ef-16a639c17119/Sentron-Software-Quickselection-Guide-EN.pdf) | SENTRON Quick Selection Guide

### Technical support

[Support Request](https://sieportal.siemens.com/en-ww/mysieportal/support-requests/create?lc=en-WW) (global)

[Support Request](https://sieportal.siemens.com/en-us/mysieportal/support-requests/create?_nct=1681915919&si=true&lc=en-US) (US-market)

[

![SENTRON 3WA air circuit breakers provide advanced protection, high selectivity and reliable availability for industrial systems](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/58QohPlfto1prX2gSp12gm/en-US/1c5cc482-b841-4163-a3a8-3cae020eb76e%20-%203wa-visual-comprehensive-portfolio-promo-640x480.jpg?auto=format%2Ccompress&w=640&h=480&fit=crop&q=60)

[Image: Siemens]

### SENTRON 3WA

The SENTRON 3WA air circuit breaker offers enhanced protective functions and high selectivity for maximum system availability. Simply reliable.

](/en-us/products/sentron/3wa-air-circuit-breakers/)

[

![sentron-3va-molded-case-circuit-breakers-mccbs-product-640x480](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/5dmPyKw9hRzQPSrBWFh49e/en-US/sentron-3va-molded-case-circuit-breakers-mccbs-product-640x480.jpg?auto=format%2Ccompress&w=640&h=480&fit=crop&q=60)

[Image: Siemens]

### SENTRON 3VA molded case circuit breakers (MCCBs)

SENTRON 3VA molded case circuit breakers provide a vital foundation for intelligent, future-ready low-voltage power distribution systems worldwide.

](/en-us/products/sentron/molded-case-circuit-breakers/)

[

![Electrical circuit breaker with blue and gray casing, mounted on a metal rail against a blurred background.](https://images.sw.cdn.siemens.com/siemens-disw-assets/public/3huV7LSXM0bRN5SuIIr6Tx/en-US/sentron-com-circuit-protection-product-promo-640x480.jpg?auto=format%2Ccompress&w=640&h=480&fit=crop&q=60)

[Image: Siemens]

### SENTRON COM

SENTRON measuring and communication-capable circuit protection devices offer a smart solution for end-to-end protection of people, plants, and systems.

](/en-us/products/sentron/capable-circuit-protection-devices/)

 

## Send us a message for your request about power distribution.